Serial Number |
Drawing | Code | Old Code |
Area AL (mm²) |
Area Steel (mm) |
Area Total (mm) |
No of wires (mm) |
No of wires (Steel) |
Dia Wire Al (mm) |
Dia Wire Steel (mm) |
Dia Core (mm) |
Dia Cond (mm) |
Mass per unit length (kg/km) |
Rated Strength (kN) |
DC resistance (Ω/km) |
Final Modulus of elasticity (N/mm²) |
Coefficient of linear expansion (1/k) |
Direction of lay of external layer |
C0112A1S1038Q.FR | 1 | 28-AL1/9-ST1A | CANNA 37.7 | 28.3 | 9.42 | 37.7 | 9 | 3 | 2 | 2 | 4.3 | 8.3 | 151.5 | 16.26 | 1.0187 | 88000 | 1.71E-05 | S |
C0119A1S1060Q.FR | 2 | 38-AL1/22-ST1A | CANNA 59.7 | 37.7 | 22 | 59.7 | 12 | 7 | 2 | 2 | 6 | 10 | 276.1 | 32.7 | 0.766 | 103500 | 1.54E-05 | S |
C0119A1S1076Q.FR | 2 | 48-AL1/28-ST1A | CANNA 75.5 | 47.7 | 27.8 | 75.5 | 12 | 7 | 2.25 | 2.25 | 6.75 | 11.3 | 349.4 | 41.15 | 0.6052 | 103500 | 1.54E-05 | S |
C0119A1S1093Q.FR | 2 | 59-AL1/34-ST1A | CANNA 93.3 | 58.9 | 34.4 | 93.3 | 12 | 7 | 2.5 | 2.5 | 7.5 | 12.5 | 431.4 | 49.48 | 0.4902 | 103500 | 1.54E-05 | Z |
C0137A1S1116Q.FR | 3 | 94-AL1/22-ST1A | CANNA 116.2 | 94.2 | 22 | 116.2 | 30 | 7 | 2 | 2 | 6 | 14 | 432.5 | 43.17 | 0.3067 | 75500 | 1.80E-05 | S |
C0137A1S1147Q.FR | 3 | 119-AL1/28-ST1A | CANNA 147.1 | 119.3 | 27.8 | 147.1 | 30 | 7 | 2.25 | 2.25 | 6.75 | 15.8 | 547.4 | 54.03 | 0.2423 | 75500 | 1.80E-05 | S |
C0137A1S1182Q.FR | 3 | 147-AL1/34-ST1A | CANNA 181.6 | 147.3 | 34.4 | 181.6 | 30 | 7 | 2.5 | 2.5 | 7.5 | 17.5 | 675.8 | 64.94 | 0.1963 | 75500 | 1.80E-05 | S |
C0137A1S1228Q.FR | 3 | 185-AL1/43-ST1A | CANNA 228 | 184.7 | 43.1 | 227.8 | 30 | 7 | 2.8 | 2.8 | 8.4 | 19.6 | 847.7 | 80.54 | 0.1565 | 75500 | 1.80E-05 | S |
C0137A1S1288Q.FR | 3 | 234-AL1/55-ST1A | CANNA 288 | 233.8 | 54.6 | 288.3 | 30 | 7 | 3.15 | 3.15 | 9.45 | 22.1 | 1 072.8 | 98.58 | 0.1236 | 75500 | 1.80E-05 | S |
NOTE: Values of final modulus of elasticity and coefficient of linear expension for the conductor sizes listed in the table are used in France.
Values for the other condactor constructions may be calculated using the method given in IEC 61597.