All Aluminum Alloy Conductor AAAC type AL3

Country of use: Austria.
Conductor Standard: EN 50182.
Raw Materials Standard: EN 50183.

1
2
3
4
5

All Aluminum Alloy Conductor AAAC type AL3

Country of use: Austria.
Conductor Standard: EN 50182.
Raw Materials Standard: EN 50183.

1
2
3
4
5
Serial Number Drawing Code Old
Code
Area
(mm²)
No of
wires
Diameter
Wire (mm)
Diameter
Cond (mm)
Mass per
unit length (kg/km)
Rated
Strength (kN)
DC
resistance (Ω/km)
Final Modulus
of elasticity (N/mm²)
Coefficient of linear
expansion (1/k)
Current
carrying capacity
C0107A3025Q.AU 1 24-AL3 25 24.2 7 2.1 6.3 66.2 7.15 1.356 6 60 000 2.30E-05 135
C0107A3035Q.AU 1 34-AL3 35 34.4 7 2.5 7.5 93.8 10.14 0.957 2 60 000 2.30E-05 169
C0107A3050Q.AU 1 49-AL3 50 49.5 7 3 9 135.1 14.6 0.664 7 60 000 2.30E-05 210
C0119A3070Q.AU 2 66-AL3 70 65.8 19 2.1 10.5 180.7 19.41 0.502 6 57 000 2.30E-05 255
C0119A3095Q.AU 2 93-AL3 95 93.3 19 2.5 12.5 256 27.51 0.354 6 57 000 2.30E-05 320
C0119A3120Q.AU 2 117-AL3 120 117 19 2.8 14 321.2 34.51 0.282 7 57 000 2.30E-05 365
C0137A3150Q.AU 3 147-AL3 150 147.1 37 2.25 15.8 405.3 43.4 0.225 6 57 000 2.30E-05 425
C0137A3185Q.AU 3 182-AL3 185 181.6 37 2.5 17.5 500.3 53.58 0.182 7 57 000 2.30E-05 490
C0161A3240Q.AU 4 243-AL3 240 242.5 61 2.25 20.3 670.3 71.55 0.137 3 55 000 2.30E-05 585
C0161A3300Q.AU 4 299-AL3 300 299.4 61 2.5 22.5 827.5 88.33 0.111 2 55 000 2.30E-05 670
C0161A3400Q.AU 4 400-AL3 400 400.1 61 2.89 26 1105.9 118.04 0.083 2 55 000 2.30E-05 810
C0161A3450Q.AU 4 452-AL3 450 451.5 61 3.07 27.6 1247.9 133.2 0.073 7 55 000 2.30E-05 870
C0161A3500Q.AU 4 500-AL3 500 499.8 61 3.23 29.1 1381.4 147.45 0.066 6 55 000 2.30E-05 930
C0191A3625Q.AU 5 626-AL3 625 626.2 91 2.96 32.6 1737.7 184.73 0.053 4 55 000 2.30E-05 1075
C0191A3800Q.AU 5 802-AL3 800 802.1 91 3.35 36.9 2225.8 236.62 0.041 7 55 000 2.30E-05 1255
C0191A31000Q.AU 5 1000-AL3 1000 999.7 91 3.74 41.1 2774.3 294.91 0.033 4 55 000 2.30E-05 1450

NOTE 1 Direction of lay of external layer is rigth hand (Z).
NOTE 2 Values of final modulus of elasticity and coefficient of linear expansion of the conductor sizes listed in the table are used in Austria.
Values for other conductor constructions may be calculated using the method given in IEC 61597.
NOTE 3 Guideline values of current carrying capacity are valid up to a frequency of 60 Hz, assuming a wind velocity of 0.6 m/s,the effect of solar radiation for Austria, an initial ambient temperature of 35 C and a conductor temperature of 80 C.For special application, when there is no air turbulence, the values should be reduced by 30%.

Product Categories
  • Steel cables
  • Conductors
  • Military security fences
  • Lifting accessories
Pages
  • Home
  • about
  • Projects
  • Contact Us
  • Accessibility Statement
Contact us

6 Baale Melacha Street
Netivot, Israel

  • Email: contact@mysite.com
  • Phone: 972-8-9943666
  • Phone: 972-8-9942997